The lever type matters too. Close-coupled cisterns almost always use a side lever or a push button through the lid, while older low-level suites more often run a side lever connected by an external link arm. Ordering a replacement lever without checking which type is fitted is a common cause of parts being sent back.
A cistern that never quite stops filling is one of the most common callouts a plumber gets, and the fix hinges on correctly identifying which of two components has failed: the fill valve or the flush valve. Get this wrong and you swap a part that was never the problem, then head back out a second time.
The third check is worth doing before assuming either fault: isolate the water supply to the cistern, remove the fill valve, and inspect the seat and washer directly for scoring, grit or mineral buildup, particularly in hard water areas where limescale narrows the valve opening over months. A valve that looks visibly worn or scaled at the seat is the straightforward fix. A valve that looks clean and undamaged but the noise persists points more strongly toward mains pressure as the underlying cause.
A side-entry fill valve takes its supply through the side wall of the cistern, typically a few centimetres up from the base, with the water pipe running horizontally into the tank. This is the older and still very common arrangement in UK homes, particularly where the supply pipe rises through a wall cavity or runs along a skirting board before turning up into the cistern. Side-entry valves are usually the easier option where floor space beneath the cistern is tight, since there is no need for the pipe to come straight up from below.
You can find out more via buy plumbing parts online.
A cistern that whistles, knocks or hammers while filling is one of the more annoying faults a customer will report, and it is also one of the quicker ones to run down with a short checklist before a plumber even gets to the van. Two causes account for the large majority of noisy-cistern callouts: a worn fill valve and excessive mains pressure, plumb2u.com and telling them apart early saves time on site.